Brand logo
HomeGlobal MarketsSector DeepDivesCompany WatchMarket EntryData Stories
  1. Home
  2. /
  3. datastories
  4. /
  5. hvdc-congestion-rules-before-switch-on

Case File: 6 GW of HVDC, 8 TWh Curtailed, and the Congestion Rules Still Missing | DataStories

Short answer: a high-voltage direct current corridor does not become a bankable asset when the converter station is energised. It becomes bankable when three documents exist: the congestion cost allocation formula, the curtailment compensation method, and an availability guarantee with named exclusions. The cases assembled below show what happens when they do not exist. Engineering milestones get announced on schedule, and the settlement logic arrives late, written retroactively on the first disputed invoice.

For readers who treat grid news as a balance-sheet event, the pattern repeats across markets: public engineering detail, private commercial detail. GlobalBizSight DataStories lined up five records — an Indian corridor award, United States congestion estimates, a Chinese southbound link, fleet-level availability statistics, and a European rule reversal dated April 2026 — to test one narrow claim: publishing settlement rules before commercial operation is a design decision, not a regulatory afterthought.

Case 1 · Barmer to South Kalamb: a complete engineering record, an empty settlement page

PowerGrid Corporation of India Limited selected GE Vernova to build a 6 GW ±800 kV HVDC link from Barmer, Rajasthan, to South Kalamb for renewable delivery. The published scope is unusually thorough: a bipolar arrangement of 2 times 3000 MW, new converter stations, supply of major equipment, site erection, testing, commissioning, the eLumina control system, and LCC valves made at Pallavaram. The award is dated to the fourth quarter of 2026, according to the trade coverage of the order.

Read as data, that record answers every procurement question and almost none of the revenue questions. Who pays when the path turns scarce? Who absorbs the cost when renewable output is ordered down? What happens to a hedge when availability falls short of its promise? A converter station transfers energy; a corridor transfers obligations as well. Barmer is the cleanest evidence available that the missing dataset is commercial, not technical.

Case 2 · United States: a 17 billion dollar bill next to a curtailment number nobody publishes

Congestion has moved from network symptom to operating line item. Transmission congestion costs in the United States were estimated to exceed 17 billion dollars in 2025, up from 12 billion dollars in 2024 — roughly a 42 percent expansion of the cost pool in one year, and the yardstick against which every new corridor will now be judged.

The asymmetry is the finding. The congestion bill is measured annually; the curtailment bill is not. A market monitoring note from S&P Global Market Intelligence states that PJM Interconnection does not reliably report curtailment figures, even as congestion charges in the same region climb. By contrast, the Texas grid publishes more: combined wind and solar curtailment in ERCOT exceeded 8 TWh in 2024, with the West zone alone losing 3.1 TWh of wind and 2.2 TWh of solar, and the US Energy Information Administration has projected that ERCOT wind curtailment could reach 13 percent of total available wind generation by 2035.

Two consequences follow for corridor buyers. First, a link sold as a congestion reliever enters a market where one half of the risk is priced and the other half is undocumented. Second, curtailment compensation is a data claim before it is ever a legal claim: the operator must state how forced curtailment is separated from economic curtailment, how dispatch order is recorded, how a generator documents lost production, and whether fuel cost, opportunity cost or contract adjustment enters settlement. Where the metering trail is thin, the compensation argument fails on evidence rather than on merit.

Case 3 · Yunxiao: a fixed toll in the month Guangdong passed 170 GW

China supplies both halves of the allocation argument, and that is what makes it instructive. On the measurable side, a summary of Chinese grid operation reports that annual average congestion duration on 500 kV and above lines fell 43 percent in 2020, while the number of cross section flow exceedances fell 68 percent. Centralised optimisation demonstrably reduces visible congestion.

On the price-signal side, a Tencent News report describes the Yunxiao link as carrying a fixed annual capacity charge of 230 million yuan, shared half by Fujian and half by Guangdong, plus a fixed toll of 0.0256 yuan per kilowatt hour for other market participants. In the same account, Guangdong load reached historical highs three times in June and became the first province to exceed 170 gigawatts, while the flat toll recorded no scarcity at all. The report is a media account, so the policy detail needs confirmation by the operator before anyone builds it into a model. The direction, however, is familiar from corridors on other continents.

The mechanism worth keeping is this: a headline toll can look simple while the decisive logic sits buried underneath. Nodal pricing advocates can invoke the principle that the party causing congestion should pay for it; users often find the resulting price signals hard to interpret when they do not map cleanly to observed grid conditions. Centralised optimisation can lower visible congestion and still spread cost in forms that participants do not read as prices. Publishing the allocation formula early lets everyone test caps, floors, settlement intervals and uplift treatment before long-term contracts are signed. It is the same discipline this site asked for when scoring a latency record that lacked a public test rulebook.

Case 4 · Availability: 95.802 percent, 26 forced outages, 437.58 hours

Capital is forming around HVDC faster than operating rules mature. One market report projects the HVDC transmission systems market rising from 13.4 billion dollars in 2026 to 19.0 billion dollars by 2033 at a 5.1 percent compound annual growth rate; another projects 14.01 billion dollars in 2024 expanding to 22.07 billion dollars by 2030 at 7.2 percent. Both are scenario markers, not forecasts to underwrite.

Fleet statistics show what a real availability series looks like once it exists. China's electricity industry reliability reporting for 2024 states that the 50 in-service HVDC transmission systems covered by the statistics posted a combined energy availability of 95.802 percent, down 1.012 percentage points year over year, while combined energy utilisation reached 48.75 percent, up 6.68 percentage points. Those systems logged 26 forced outages with a cumulative equivalent outage duration of 437.58 hours; point-to-point ultra-high-voltage links reported 94.884 percent availability, down 2.138 percentage points.

Three readings from that table of numbers: availability eroded even as utilisation improved; the ultra-high-voltage segment was the softer one; and a 95.802 percent headline says nothing about the event mix hidden behind it. European transmission operators have gone the opposite way on transparency, since ENTSO-E publishes an annual HVDC utilisation and availability statistics report covering Nordic and Baltic links. A developer negotiating a corridor contract should be able to request that class of link-level dataset as a baseline, not as a favour.

Supply chain pressure turns reliability into a contract term. A grid and cable investment review records that HVDC cable prices rose 50 percent in a period and delivery lead times tripled. Repair time is the hidden variable in every availability clause: if a valve, transformer or cable section takes three times longer to replace than it did at contract signature, an availability guarantee without categories for forced outage, planned outage, partial derate, weather, fuel delivery, grid instruction and market curtailment is a marketing term. It promises a headline rate without naming the events that count against it.

Case 5 · Germany, 29 April 2026: the strongest objection, documented

The best data available supports the counterargument that early rulebooks can freeze the wrong answer. On 29 April 2026 the German federal cabinet approved a draft law lifting the country's underground cable priority for new HVDC corridors, reversing a compromise dating from 2015, as reported by HVDC World and opposed by the cable industry association Europa Cable. Clean Energy Wire reported the government's framing of the switch as the lower-cost route that should ease network charges for consumers over time. Whichever side is right, no corridor settlement formula drafted a few years earlier predicted that variable.

The governance gap is broader than one country. ACORE says United States HVDC deployment lags because of permitting, cost-allocation and regulatory barriers, and offers nine recommendations — an acknowledgement that the rules themselves are still in motion.

That is an argument for a provisional rulebook, not for silence. A corridor can publish a default algorithm, a sample settlement sheet, a curtailment formula and an availability schedule, each carrying a stated recalibration period. Participants get a starting model; engineers keep discretion. If nothing is published, participants do not escape rigidity either. They absorb the first loss and then argue about which rule applied afterwards.

Where the case stops applying

The claim should stop at the edge of the evidence. A small radial link, owned by one regulated utility and used only to export one renewable portfolio under a simple contract, can be handled inside the utility rate case, with curtailment managed through the dispatch instruction; a published rulebook there may add cost without adding information. The same holds where a central system operator already publishes audited settlement rules and transparent after-the-fact cost allocation, even if the founding document is short enough to read in one sitting.

Publication becomes necessary when three conditions stack at once: multiple users share the path, public funding sits inside the project, or merchant renewable export depends on scarce capacity. At that point the corridor stops being infrastructure and becomes a capacity instrument inside someone else's dispatch — which is why long-lived grid assets also need clarity on how their costs are spread across ratepayer generations.

Common misconceptions when reading corridor data

  • Less measured congestion means less cost. The 43 percent fall in 500 kV-and-above congestion duration in 2020 proves optimisation works on the symptom, not that the bill vanished. Allocation may simply change shape.
  • A simple toll is a neutral toll. Yunxiao's flat charge ran unchanged while Guangdong set three load records in one month.
  • A high availability headline is low risk. 95.802 percent across 50 systems coexisted with 26 forced outages; the number that matters is the exclusion list and the repair window.
  • Curtailment is a legal event. It begins as a metering and record-retention question, and only later becomes litigation.
  • Publishing rules early removes flexibility. The alternative to a published rule is not flexibility. It is retroactive interpretation, priced by whoever loses first.

What to demand before energisation: the three-document package

DocumentMinimum contentWhen it should be publicFailure mode if missing
Congestion cost allocationHourly settlement, or the shortest interval available locally; basis stated as node price, post-dispatch uplift, zonal charge or centralised optimisation penalty; caps, floors and uplift treatment; worked examples for normal, peak and low demand; whether a third party may request a settlement calculation and the response deadlineBefore commercial operationDevelopers hedge on assumptions; the first scarce hour becomes an argument about which rule applied
Curtailment methodDefinitions of forced and economic curtailment, metering standard, dispatch record retention, settlement delay, compensation basis and appeal routeBefore the first renewable block is scheduledCompensation claims fail on evidence, and public funders cannot separate a windfall from a genuine loss
Availability guaranteeExpected rate, exclusions, repair windows, derate categories covering hardware failure, control system downtime, curtailment instruction and third-party work, consequences for repeated shortfallsAlongside the equipment and O&M contractThe headline rate survives the dispute; the revenue does not

Regular reporting should then cover forced outage hours, planned outage hours, availability, curtailment hours and congestion cost recovery in one series, so the same outage cannot become congestion rent for one party and curtailment compensation for another. Public funders need that same series: milestone reports tell them whether a corridor was built, while availability and curtailment reporting tells them whether it performs. The remedy follows the diagnosis — engineering work for one failure, a tariff review for the other.

Frequently asked questions

Why does the timing of settlement rules matter more than the rules themselves?

Because an HVDC link is a capacity asset whose settlement logic can shape revenue for a decade. A developer signing a hedge, a lender sizing a reserve margin and an agency evaluating a grid subsidy all model from the same starting point: what the corridor charges when it is scarce, and what it pays when it is not delivering.

Are congestion cost and curtailment cost the same number?

No. They describe different pockets of risk. Congestion was measured above 17 billion dollars for the United States in 2025, while curtailment in the same country is reported unevenly — PJM's figures are called unreliable by market monitors, whereas ERCOT's curtailment volumes are published and exceeded 8 TWh in 2024. A corridor can reduce one and worsen the other.

What does an availability guarantee usually leave out?

The event list. Forced outage, planned outage, partial derate, weather, fuel delivery, grid instruction and market curtailment are rarely separated, even though China's 2024 fleet data — 26 forced outages and 437.58 equivalent outage hours — shows that category-level reporting is technically feasible.

Should every new corridor publish a rulebook?

No. Small radial links under a single regulated owner, and corridors already covered by audited operator settlement, do not need a new document. The test is shared capacity plus public money plus merchant export.

Which single metric should an analyst watch first?

The gap between energy utilisation and energy availability. In the 2024 Chinese fleet data, utilisation rose 6.68 percentage points while availability fell 1.012 percentage points — a combination that points to scarce, high-value hours running through assets that are not fully available.

References

  • GE Vernova Selected by PGCIL to Build a 6 GW HVDC Corridor from Barmer to South Kalamb
  • Transmission Congestion for 2025, Grid Strategies
  • Baidu Baike entry on congestion charges
  • Curtailment, congestion costs rise as transmission upgrades lag renewable growth
  • Tencent News report on interprovincial transmission pricing
  • Persistence Market Research HVDC transmission systems market
  • MarketsandMarkets HVDC grid market trends
  • Energy transition will depend on cables
  • ACORE report on U.S. HVDC transmission deployment
  • 2024 national power reliability indicators, China Electricity Council reporting
  • US EIA: as Texas wind and solar capacity increases, energy curtailments are also likely to rise
  • FactSet Insight: ERCOT curtailments persist as load rises
  • ENTSO-E HVDC Utilisation and Availability Statistics 2024
  • HVDC World: Germany lifts undergrounding mandate for new HVDC corridors
  • Clean Energy Wire: Germany plans switch from underground to overhead lines
  • Europa Cable response to the German cabling decision

Related reading

  • DataStories Case File: What China's 360 Terawatt-Hour Curtailment Teaches Investors About Grid Risk
Brand logo

Global Biz Sight

Global business intelligence — turning scattered data into clear, actionable decisions.

Global MarketsSector DeepDivesCompany WatchMarket EntryData StoriesGlobal SaaSManager

© 2026 GlobalBizSight.

Cookie Notice

We use cookies to improve your experience and analyze website traffic. Read our Privacy Policy to learn more.